Power Supply | AC: 85V~265V, DC: 12~25V; Two power supply methods |
Lithium Battery supply module TP1700V | 12V 4000mAh lithium-polymer battery, DC voltage output 12.6V (optional) |
Power consumption | ≤25W (Actual power consumption is related to the numbers of channel) |
Numbers of channel | 1~64 channel ( Can expand to 200 channels) |
Input signal (Refer to the module selection table below: Function description) |
Thermocouple: K,R,B,N,E,T,J,S,WRE5-26,WRE3-25 |
Thermal resistor: Pt1000, Pt100 | |
DC current: 4~20mA, 0~20mA | |
DC voltage: 0~5V, 0~10V, ±20mV, ±100mV | |
Isolation, withstand voltage and temperature measurement | AC/DC 400V (also applicable to voltage difference between channels) |
Storage interval | 1~19999s self-setup |
Recording memory | 4G(TP700 Basic Module) |
8G(TP1000 Basic Module) | |
Recording mode | Cycle record |
Alarm type | Upper and lower alarm, each channel has 4 types,(ultimate upper,upper,ultimate lower,lower) |
Relay | 8 channel normal close relay 250V/2A |
Power supply output | 1 channel DC 24V power supply |
Communication | Standard ethernet, RS485,RS232 (optional USB,4G/WiFi wireless communication,Standard Modbus TCP communication protocol) |
Standard Modbus RTU protocol | |
Operation environment | -20ºC~70ºC 0~90% RH (No condensation) |
Storage environment | 0ºC~50ºC 0~85%RH(No condensation) |
Host material | Fireproof ABS |
Dimension | 288*288*200mm |
Installing opening hole size | 278*278mm+1 |
Module name | Model No. | channel | Function description |
Universal signal input module (Basic Module) Sampling speed: 1S |
TP1708P2.1 | 8 | Thermocouple: K,T,J,E,S,B,R,N,WRe3,WRe5 |
Thermal resistor: Pt100,Pt1000 | |||
DC Voltage 0~5V,0~10V, ±100mV,±20mA | |||
DC current 4~20mA, 0-20mA | |||
Fast acquisition module Sampling speed: 0.1s |
TP1708P1 | 8 | Thermocouple: K,T,J,E,S,B,R,N,WRe3,WRe5 |
Thermal resistor: Pt100,Pt1000 | |||
DC Voltage 0~5V,0~10V, ±100mV,±20mA | |||
DC current 4~20mA, 0-20mA | |||
DC voltage acquisition module | TP1758 | 8 | Support DC voltage: 0~120V accuracy: 0.5%, resolution 1mV(Can customized: 0-300V) |
DC current acquisition module | TP1748 | 8 | Support DC current: 0~10A (range can be customized) accuracy: 0.5% resolution 1mA |
AC power parameter acquisition module | TP1706V1 | 1 | Measure single-phase AC and DC power (including voltage, current, power, frequency, power factor and other data, voltage range 5-1000V, current 10mA-20A, frequency 45-400HZ) |
Three-phase power acquisition card | TP1707 | 1 | Measure three-phase AC (including voltage, current, power, frequency, power factor, power consumption and other data, voltage range 5-1000V, current 1mA-20mA, frequency: 1-400HZ) Remarks: 1A-1000A (Rogowski coil current transformer); 1mA-20mA (high ratio transformer) |
Temperature and humidity acquisition module | TP1728 | 8 | Support TP2305V2 temperature and humidity sensor(range -20ºC~125ºC accuracy ±0.3ºC) |
Relay alarm output module | TP1708J | 8 | 8-way normally open and normally closed relay contact output, overload 250V 2A |
Switch input module | TP1708K | 8 | 8-way switch signal input, wet contact, 5-24V |
Recorder Dedicated battery module | TP1701 | / | A battery module could supply 8 channel record to work 10H continuously,adopt 12V,4000mAH large capacity battery, could plug more battery modules and extend testing time. |
Wireless IOT module | TP1702V3/ V4 |
/ | WiFi and 4G two wireless communication methods, upload data to the cloud platform to monitor data logger data |
NTC temperature sensor acquisition module | TP1708NTC | 8 | Support NTC temperature sensor,multiple specification, 3600,3950,3425,3435 ect on. (Can customized) |
Input Type | Measuring range (indication range) |
Measurement accuracy (reference error, absolute error) |
Digital display resolution | ||
DC voltage | 0-10V | -0.5V to+11.000V | 0.01% F.S. ±0.002V | Maximum 6 digits | |
0-5V | -0.5V to+5.500V | 0.01% F.S. ±0.002V | Maximum 6 digits | ||
±100mV | -110.0mV to+110.0mV | 0.005% F.S. ±0.005mV | Maximum 6 digits | ||
±20mV | -21.0mV to+21.0mV | 0.005% F.S. ±0.005mV | Maximum 6 digits | ||
DC Current | 4-20mA | +3mA to+21.00mA | 0.01% F.S. ±0.001mA | Maximum 6 digits | |
0-20mA | 0.00mA to+21.00mA | 0.01% F.S. ±0.001mA | Maximum 6 digits | ||
Measurement accuracy (relative error) | Maximum 6 digits | ||||
Thermocouple | K | -60ºC to+1372ºC | ±(0.1% rdg. +1ºC) | Maximum 6 digits | |
J | -200ºC to+1200ºC | ±(0.1%rdg.+1.0ºC)≤0ºC±(0.15%rdg.+1.0ºC) | Maximum 6 digits | ||
E | -200ºC to+1000ºC | ±(0.1%rdg.+1.0ºC)≤0ºC±(0.15%rdg.+0.5ºC) | Maximum 6 digits | ||
T | -200ºC to+400ºC | ±(0.1%rdg.+1.0ºC)≤-30ºC±(0.15%rdg.+0.5ºC) | Maximum 6 digits | ||
N | -200ºC to+1300ºC | ±(0.1%rdg.+1.0ºC)≤0ºC±(0.3%rdg.+0.7ºC) | Maximum 6 digits | ||
W | +1500ºC to+2315ºC | ±(0.05% rdg. +1.5ºC) | Maximum 6 digits | ||
0ºC to+1500ºC | ±(0.05% rdg. +1.0ºC) | Maximum 6 digits | |||
R | +800ºC to+1768ºC | ±(0.05% rdg. +1.5ºC) | Maximum 6 digits | ||
+400ºC to+800ºC | ±(0.2% rdg. +2.0ºC) | Maximum 6 digits | |||
S | +800ºC to+1768ºC | ±(0.05% rdg. +1.5ºC) | Maximum 6 digits | ||
+400ºC to+800ºC | ±(0.2% rdg. +2.0ºC) | Maximum 6 digits | |||
B | +800ºC to+1820ºC | ±(0.05% rdg. +1.5ºC) | Maximum 6 digits | ||
+400ºC to+800ºC | ±(0.2% rdg. +2.0ºC) | Maximum 6 digits | |||
Thermal resistor | Pt100 | -200ºC to+660ºC | ±(0.02% rdg. +0.3ºC) | Maximum 6 digits | |
Cu50 | -50ºC to+150ºC | ±(0.02% rdg. +0.3ºC) | Maximum 6 digits | ||
PT1000 | -200ºC to+300ºC | ±(0.05% rdg. +0.2ºC) | Maximum 6 digits | ||
Warm-up time | More than 30 minutes | ||||
Thermocouple Measurements | Including cold junction compensation accuracy | ||||
Standard operating conditions (accuracy as above) |
Temperature 25±3ºC, humidity 55±10%RH | ||||
Environmental adaptability | Operating temperature | -20ºC to +60ºC | |||
Operating humidity | 0 to 95% RH (no condensation) |
The TP700 paperless recorder, with its excellent data collection capabilities, can record the various operating parameters of the reverse osmosis system in real time and accurately. Whether it is the stable fluctuation of pressure, the subtle adjustment of flow, or the subtle change of temperature, it is captured and recorded one by one. These data, like the "physical examination report" of the system, provide an important reference for evaluating system performance and timely discovering potential faults.
Established in 2009, which is covering an area of over 3000 square meters, has 6 work lines and many staffs who have good research, design for techniques, quality controlling and production.
Business Scope: data logger, humidity & temperature logger/sensor, gas detector, pressure sensor, water level meter, liquid level transmitter, data acquisition moduel, IoT gateway, thermal imaging camera, power& energy meter/power quality analyzer etc.
And we have the advanced examine equipment, product technique and the perfect quality protect system. Beside our brand name products, we also have more than 15 years' ODM and OEM order experience and can accord the clients demands or requirements to personalized own brand.
Sincerity and Down-to-earth working approach' to provide clients with excellent service of processing! We sincerely welcome you to visit our company or contact us for cooperation!
Warmly welcome you and opening up the boundaries of communication. We synchronize with your ideal partner!
Q: Are you a factory/manufacturer?
A: Yes, We are professional factory/manufacturer of data logger, humidity & temperature logger/sensor, gas detector, pressure sensor, water level meter, liquid level transmitter, data acquisition moduel, IoT gateway, thermal imaging camera, power& energy meter/power quality analyzer etc.
Q: Can I customized my logo and different communication methods?
A: Yes,For customized logo that will be okay,but there is a small MOQ. For communication methods: GPRS, 4G, WIFI, LORA, LORAWAN etc. Please keep us informed in advance.
Q: How long is your lead time? If I want to customize instruments, how long will it take?
A: Usually, we can ship out within 3-5 days after receiving your payment. The customize device is depends on your order quantity.
Q: What payment method do you accept?
A: We accept payment method of T/T (bank transfer), Western Union, PayPal and so on.
Q: What package do you use for your products? What shipping method do you use?
A: 1. We use standard carton box for packing.
2. We ship via express courier (door to door service), by air, and by sea according to customers' requirements.
Q: How is your company's product after-sales service system?
A: The product warranty period is 12 months, we can provide lifetime maintenance. And we have professional pre-sales and after-sales engineer teams one-to-one after-sales servicethat can respond to you within 24 hours to resolve technical issues.
For more questions, please feel free to send inquiries to us.