0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples

Product Details
Customization: Available
After-sales Service: We Can Provide Lifetime Maintenance
Warranty: 1 Year
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Quality Assurance
The supplier provides quality assurance
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO14001
FIVE STARS Certificate
IEC Certificate
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (33)
  • 0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
  • 0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
  • 0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
  • 0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
  • 0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
  • 0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
Find Similar Products
  • Overview
  • Paperless recorder parameters
  • Data acquisition moduel
  • Acquisition Range and Accuracy
  • Product Description
  • Data logger testing report
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
TP1000H
Customized
Customized
Certification
RoHS, CE, ISO
IP Rating
IP54
Screen Size
10inch
SD Card Memory Size
8G
Measuring Medium
Simultaneous Testing Temp, Humidity, Current etc
Type
Paperless Logger
Channels
8-64 Channels (Can Be Expanded to 200 Channels)
Communication
RS485, RS232, Ethernet, 4G, WiFi, Lorowan)
Support
Software, Platform and APP View Data
Support Input
0-5V, 4-20mA, Thermocouple, Thermal Resistor
Transport Package
Carton Box
Specification
41*37*28cm
Trademark
Toprie
Origin
Shenzhen
HS Code
9031809090
Production Capacity
100000

Packaging & Delivery

Package Size
41.00cm * 37.00cm * 28.00cm
Package Gross Weight
8.500kg

Product Description

Paperless recorder parameters
In order to test the isolation voltage of two adjacent thermocouple wires, we connect the ground wire of the withstand voltage machine and the ground wire of the pressure measuring device to a thermocouple together;

At the other sampling end, the positive wire of the withstand voltage machine is connected to the test end of the other thermocouple, and the positive wire of the pressure measuring device is manually measured at the connection terminal of the thermocouple.

The voltage measured in this way is the isolation voltage of the two thermocouple wires.
0.01s High-Speed Data Logger for The Isolation Voltage Between ThermocouplesAfter all the equipment is turned on and the voltage of the withstand voltage machine is adjusted to 1200V, we can clearly monitor that the equipment is working normally, and the data collected by TP1000 through the 1704 acquisition module is stable.

The data curve interface is also stable, indicating that the high voltage has not affected the normal operation of the equipment.
Power Supply AC: 85V~265V, DC: 12~25V; Two power supply methods
Power consumption ≤25W (Actual power consumption is related to the numbers of channel)
Numbers of channel 1~32 channel ( Can expand to 64channels)
Input signal Thermocouple: K,R,B,N,E,T,J,S,WRE5-26,WRE3-25
(Refer to the module selection table below: Function description) Thermal resistor: Pt1000, Pt100
DC current: ±120mA
DC voltage: ±120V, ±20V, ±100mV ±20mV
Isolation, withstand voltage and temperature measurement AC/DC 1500V (also applicable to voltage difference between channels)
Storage interval 1~19999s self-setup
Recording memory 8G(TP1000 Basic Module)
Recording mode Cycle record
Alarm type Upper and lower alarm, each channel has 4 types,(ultimate upper,upper,ultimate lower,lower)
Communication Standard ethernet, RS485,RS232
(optional USB,4G/WiFi wireless communication,Standard Modbus TCP communication protocol)
Standard Modbus RTU protocol
Operation environment -20ºC~70ºC     0~90% RH (No condensation)
Storage environment 0ºC~50ºC    0~85%RH(No condensation)
Host material Fireproof ABS
Dimension 288*288*200mm
Installing opening hole size 278*278mm+1
Dimension 288*288*200mm
Installing opening hole size 278*278mm+1
0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
Data acquisition moduel
Data sampling port characteristics Mechanical properties
Number of channels: 4 differential Shell material: ABS
AD level: 24-bit high-precision dedicated IC Shell color: gray green
Sampling mode: Each channel is sampled independently Size: 130*93*42mm
Sampling rate: 100HZ Housing installation method: embedded
Channel-to-channel isolation voltage: 1500V AC/DC Protection level: IP40
Isolation voltage from power supply: 1500V DC Fire rating: UL94
Communication interface characteristics Certification information
RS-485 Communication Passed CE, FCC, ROSH certification
Environmental characteristics
Working environment: -20ºC~50ºC 0~90%RH without condensation
Storage environment: 0ºC~50ºC 0~85%RH without condensation
Acquisition Range and Accuracy
Input Type Measuring range
(indication range)
1S+0.1S 0.01S
DC voltage ±120V -132V to+132V 0.01% F.S.±0.002V 0.01% F.S.±0.005V
±20V -22V to+22V 0.01% F.S.±0.002V 0.01% F.S.±0.005V
±100mV -120.0mV to+120.0mV 0.01% F.S.±0.005mV 0.01% F.S.±0.015mV
±20mV -25mV to+25mV 0.01% F.S.±0.005mV 0.01% F.S.±0.015mV
DC Current ±120mA -23mA to +23mA 0.01% F.S.±0.002mA 0.01% F.S.±0.003mA
Thermocouple measurement accuracy 
Absolute error measurement requires standby for more than 30 minutes in a static environment with a room temperature of 25 degrees and a humidity of 20%-80%.
Thermocouple K -60ºC to+1372ºC ±(0.1% rdg. +1.0ºC) ±(0.1% rdg. +1.5°C)
J -200ºC to+1200ºC ±(0.1% rdg. +1.0ºC) ±(0.1% rdg. +1.5°C)
E -200ºC to+1000ºC ±(0.1% rdg. +1.0ºC) ±(0.1% rdg. +1.5°C)
T -200ºC to+400ºC ±(0.1% rdg. +1.0ºC) ±(0.1% rdg. +1.5°C)
N -200ºC to+1300ºC ±(0.1% rdg. +1.2ºC) ±(0.1% rdg. +1.8°C)
W +1500ºC to+2315ºC ±(0.05% rdg.+1.5°C) ±(0.05% rdg.+2.0°C)
0ºC to+1500ºC ±(0.05% rdg.+1.0°C) ±(0.05% rdg. +1.5°C)
R +800ºC to+1768ºC ±(0.05% rdg.+1.5°C) ±(0.05% rdg.+2.0°C)
+400ºC to+800ºC ±(0.2% rdg. +2.0°C) ±(0.2% rdg. +2.5°C)
S +800ºC to+1768ºC ±(0.05% rdg.+1.5°C) ±(0.05% rdg. +2.0°C)
+400ºC to+800ºC ±(0.2% rdg. +2.0°C) ±(0.2% rdg. +2.5°C)
B +800ºC to+1820ºC ±(0.05% rdg.+1.5°C) ±(0.05% rdg.+2.0°C)
+400ºC to+800ºC ±(0.2% rdg. +2.0°C) ±(0.2% rdg. +2.5°C)
Thermal resistor Pt100(3-wire) -200ºC to +660ºC ±(0.02% rdg. +0.3°C) ±(0.02% rdg. +0.4°C)
Pt100(4-wire) -200ºC to +660ºC ±(0.02% rdg.+0.2°C) ±(0.02% rdg. +0.3°C)
PT1000(3-wire) -200°C to +300°C ±(0.02% rdg. +0.3°C) ±(0.02% rdg. +0.4°C)
PT1000(4-wire) -200°C to +300°C ±(0.02% rdg. +0.2°C) ±(0.02% rdg. +0.3°C)
Warm-up time More than 30 minutes
Thermocouple Measurements Including cold end compensation accuracy + away from heat source + away from wind source
Standard operating status
<Precision above>
Temperature 25±3ºC, humidity 50±30%RH, power supply 9-28VDC
Environmental adaptability -20ºC to +50ºC, 0 to 90% RH (no condensation)
Communication RS485,RJ45,CANFD,4G,ZigBee,WiFi,Thread,USB
Product Description

0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples
0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples

Data logger testing report

0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples

Company Profile

Shenzhen Toprie Electronics Co., Ltd. is a leading high-tech enterprise specializing in the development and manufacturing of environmental monitoring and data acquisition solutions.

Established in 2009, our company operates a state-of-the-art facility spanning over 3,000 square meters, equipped with six advanced production lines and a highly skilled team committed to research, design, quality control, and precision manufacturing.

Core Business
We provide a comprehensive portfolio of cutting-edge products, including:

Multi-Channel Data Loggers & Paperless Recorders

Humidity & Temperature Sensors and Loggers

Gas Detectors

Multi-Parameter Cleanliness Analyzers

Smart Wireless Pressure & Temperature Sensors

Smart Water Meters

Water Level Meters, Ultrasonic Level Meters & Radar Level Meters

Multi-Channel Data Acquisition Modules (DAS & DAQ)

Smart IoT Gateways & Edge Computing Gateways, RTU, and DTU

SCADA Systems, HMI & HDMI Solutions

Thermal Imaging Cameras & Infrared Temperature Sensors

Electric, Power, and Energy Meters / Power Quality Analyzers

Comprehensive IoT Solutions

Quality & Customization
With advanced testing facilities, state-of-the-art manufacturing technologies, and a rigorous quality assurance system, we ensure that every product meets the highest industry standards.

In addition to our proprietary product line, we offer OEM and ODM services, providing customized solutions tailored to our clients' specific requirements, including personalized branding.

Our Commitment
Driven by integrity, innovation, and excellence, we are dedicated to delivering high-quality products and exceptional customer service. We welcome you to visit our company or contact us to explore potential collaboration opportunities.
0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples0.01s High-Speed Data Logger for The Isolation Voltage Between Thermocouples

FAQ

Q: Are you a factory/manufacturer?
A: Yes, we are a professional manufacturer of data loggers, humidity & temperature sensors, gas detectors, pressure sensors, water level meters, liquid level transmitters, data acquisition modules, IoT gateways, thermal imaging cameras, power & energy meters, and more.

Q: Can I customize my logo and communication methods?
A: Yes, logo customization is available with a small MOQ. We support multiple communication methods, including GPRS, 4G, Wi-Fi, LoRa, and LoRaWAN. Please inform us in advance.

Q: What is your lead time? How long for custom instruments?
A: Standard products ship within 3-5 days after payment. Custom orders depend on quantity and requirements.

Q: What payment methods do you accept?
A: We accept T/T (bank transfer), Western Union, PayPal, and more.

Q: What packaging and shipping methods do you use?
A:

Standard carton packaging

Shipping via express (door-to-door), air, or sea as per customer requirements.

Q: What is your after-sales service policy?
A: We offer a 12-month warranty and lifetime maintenance. Our professional support team provides one-on-one assistance and responds within 24 hours to resolve technical issues.

For more inquiries, feel free to contact us!